12. Disposal
The product does not belong in the household waste!
Dispose of the product according to the relevant statutory regulations at the
end of its service life.
13. Technical Data
Operating voltage..............................230 V/AC , 50 - 60 Hz
Connection output.............................3680 W (230 V/AC, 16 A)
Temperature switching points ........Max. 4
Programmes.......................................Weekdays Monday.....Friday
Temperature control range .............+5 °C to +45 °C
Temperature tolerance ....................±1 °C
Switching contact .............................Relay, single-pole
Ambient conditions ...........................Temperature -10 °C to +60 °C, humidity max. 90%
Sensor cable length..........................Approx. 2 m
Dimensions.........................................80 x 80 x 50 mm
Weight .................................................171 g
Weekend Saturday/Sunday
relative, non-condensing
45