MADE IN FRANCE
Trigger command connector
The trigger command socket is laid out in the following way:
TIG 200
1- Switch GND + Potentiometer
2- Cold current button
3- Welding torch button
4- Cursor / potentiometer
5- +5V potentiometer 10 KΩ
TIG 168
1- Switch GND
2- Cold current button
3- Welding torch button
REMOTE CONTROL (TIG 200 ONLY)
The remote control operates in TIG and MMA mode.
Connector technology
The TIG 200 is equipped with a female socket for a remote control. The specific 7 point male plug (GYS product
ref.045699) enables connection to a manual remote control (RC) or foot pedal (PEd).
For the cabling lay out, see the diagram below.
ref. 045699
Connecting remote/pedal
1- Power up the machine
2- Plug the pedal/remote control to the connecting socket on the machine.
3- The screen will flash and display « No » (Nothing),
4- Select the type of control by turning the intensity adjustment knob:
« No » (Nothing) / « RC »
5- Turn the knob until the desired selecton is reached, and after 2 seconds the display will freeze on the chosen selec-
tion.
Nb. : In case of error, unplug the remote control, ( « No » will be displayed) and re-start the connection
process.
Remark: You will be asked to specify the remote connected each time the machine is powered up.
Functions
Manual remote control: (GYS product ref.045675)
The remote control enables the variation of current from minimum intensity (DC : 10A / MMA : 10A) to an intensity
defined by the user.
In this configuration, all modes and functions of the machine are accessible and can be set.
Pedal (GYS product ref.045682):
In all modes excluding « Spot » mode, the pedal control enables variation of the current from the minimum intensity
(DC : 10A / MMA : 10) to an intensity definied by the user.
In TIG mode, the machine will only operate in two-stage welding (2T mode). The upslope and downslope are not auto-
matic, and are controlled by the User with the foot pedal.
In « Spot » mode, the pedal control replaces the torch trigger (the pedal position has no effect on the current).
20
TIG 168 / TIG 200 DC
(Remote Control) / « PEd »
2
3
4
1
1
4
5
D : Switch contact
C : Earth
B : Cursor
A : + 5V
Nb : The Potentiometer value must be 10 KΩ
(Pedal)
EN
3
5
2