10. Final Checklist
1) Is the icemaker level?
2) Is the icemaker in a site where the ambient
temperature is within +7°C to +40°C all year
around?
3) Is there at least a 15 cm clearance around the
icemaker for maintenance or service?
4) Have the shipping carton, tape, and packing
material been removed from the icemaker? Are
the cube guides in their correct position? Are the
separators properly attached to their holding clips?
See Fig. 7.
5) Have all electrical and piping connections been
made?
6) Has the power supply voltage been checked or
tested against the nameplate rating? And has a
proper earth been installed in the icemaker?
7) Are the water supply line shut-off valve and drain
valve installed? Has the water supply pressure
been checked to ensure a minimum of .7 bar and a
maximum of 8 bar?
Note: The icemaker may stop running when
the water supply is off, or if the pressure
is below .7 bar. When the proper water
pressure is reached, the icemaker
automatically starts running again.
8) Have the compressor hold-down bolts and
refrigerant lines been checked against vibration
and possible failure?
9) Has the bin control switch been checked for correct
operation?
10) Has the end user been given the instruction
manual, and instructed on how to operate the
icemaker and the importance of the recommended
periodic maintenance?
11) Has the end user been given the name and
telephone number of an authorized service agent?
12) Ensure all components, fasteners, and
thumbscrews are securely in place after
installation. Make sure that none have fallen into
the storage bin.
9
ENGLISH