ENG
3
ASSEMBLY
Workload data
Bending moment M
B
Vertical weight F
G
2
3
Hook rail clamp (1) on the DIN rail (2) and tighten with a
hand screw (3).
Insert 16 mm pin (4) and secure it with the plastic screw
(5).
DANGER
Danger to life through electric shock
The power cable (black) must always lead from the
top of the light arm (as shown in the image above).
All poles of the luminaire must be separated by an
external switch from the power (not included in the
delivery).
DANGER
Danger to life through electric shock
All poles of the voltage supply at the power connec-
tion must be secured via an overcurrent release (ac-
cording to national assembly regulations) (not in-
cluded in the delivery).
4
OPERATION
WARNING
Warning against damage to eyes
Never look directly into the beam of light.
DANGER
Danger to life through electric shock
Do not plug in any damaged power cables.
If there are any signs of damage to the power
cable, immediately replace it with a new one.
Connection voltage and frequency must match
data on the type plate.
12
15 Nm
32 N
4
1
5
The 180° position (parking position) is not permit-
ted.
A sharp bend of approx. 90° at the connecting piece
is not permitted.
Example for a correct parking position
►
Plug in cable
Before each use: Perform a function test: all LEDs in the
light cone must come on.
Turn luminaire on/off