If the compartment is accessible from the outside, position the insert with the base resting on the reference
surface of the compartment, pull out the monoblock, making sure it does not tip over, and secure the base with 8
anchors to the existing support surface; if a support surface is not available, the height-adjustable insert support KIT,
to be fixed to the floor with 8 anchors, is available on request.
If the compartment is not accessible, proceed as follows:
1 - remove the pullout part of the insert from the guides and the fixed base by undoing the 9 guide-fixing screws each
side, after pulling it out completely;
2 - fix the base in the reference compartment with 8 anchors, making sure it is flat-horizontal and perpendicular to
the outer wall;
3 - make connections to the flue A , the hydraulic connections and possible combustion air inlet B (available on
request) without forcing the connection parts on the base;
4 - make the electrical connection and/or ensure that the electric cable is run safely to the external outlet;
5 - after pulling out the telescopic guides from the base, refit the monoblock on them, carrying out the procedure of
step 1 in reverse order;
6 - check the sliding of the pullout part,the flexible hydraulic tubes, locking of the latch and operation of the safety
microswitch for the insert's power supply;
9 screws LH
9 screws RH
DETAIL B
RH side
40
Optional insert
support KIT
TERMOFIRE L