Description; Operation - Dustcontrol DC 3500 Manuel D'instruction

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Description

The DC 3500 is a machine with large suction capa-
city and robust construction while still being compact
and easy to maneuver.
It is ideal for spot extraction on most types of hand-
held tools and for industrial cleaning (38 mm and 50
mm system).

Operation

Connect the machine to a suitable power source
according to the specification plate on the machine.
If the electrical cord on the machine becomes
damaged it should be replaced.
The filter should be cleaned 1-2 times per day with
continuous running or if the machine is equipped with
a filter monitor, when this is in the red area.
For filter cleaning:
1. Start the machine.
2. Disconnect the hose from the suction casing.
3. Place the suction hoses free end over the filter
cleaning handle.
4. With slow, even motion open the pulse top by
depressing the handle. Repeat three to
The filter cleaning with reverse pulse gives the fine
filter extra long life and constant capacity. As well
the filter is suitable for a wide range of dusts than
earlier models. The shaker top on the older model
DC 3500 can be changed out for the new pulse
cleaning top.
four times.
5. Reconnect the hose to the suction casing.
6. If the filter condition meter reads green work
can continue, if in the red, pulse clean
again. If after several repetitions, the filter
condition still shows red the fine filter 408801
must be changed.
The plastic sack should be changed only after the
filter has been cleaned. The sack should be changed
when the dust level is about 5 cm under the foot valve.
The plastic sack should be sealed after removal from
the machine.
Use only original plastic sacks.
DC 3500 - 9
Art nr 9011

Publicité

Table des Matières
loading

Table des Matières