II - Installation of the products
2.1 Recommendations before installation
The location where the wall or ceiling sounder is to be installed must be chosen according to the
presence of PoE network cable nearby (depending on the version of the product, the cable is fed
through the back ot the product or through its top, so plan accordingly).
The identification of one or more Harmonys sounders, requires the presence of one or two
persons:
- 1 person: we recommend wiring Harmonys one by one to your bay. You can then locate the
sounder easily as long as the cable is identified.
- 2 persons: a person making the identification from software (see manual 607726). The
second person standing in the area where the Harmonys sounder is located to hear beeping in
order to identify it (eg: hallway, foyer).
2.2 Wall sounder
1 / Harmonys wall sounder is shipped open. Once installed to the wall and closed, the front panel
can be uncliped by pulling on the white plate.
Do not use tools to unclip the front.
2 / Feed the Ethernet cable through the opening in the back panel and fix the sounder in place
using the 4 screws.
4/ Make sure that the wall sounder is flat against the wall.
5/ Connect the Ethernet network cable to the RJ45 connector.
Ethernet cable category: 5 minimum or 6.
The broadcast mode will have to be selected in the Network configuration page (17) of the
embedded web server, in Multicast mode the address of the product must be the same than that
of the server (by default 239.192.55.1). Record the MAC address of the product, it will be useful
during its detection by the Sigma software in order to rename it.
Dimensions for the wall installation:
168
90
80
50
17