3.3 Parameters page

This page allows to configure the functional features of the equipment.
The information displayed is described below:
- M-CAST Address (address A and B): multicast addresses for sending melody commands
(default: A=239.192.55.1, B=left blank). If using two IP addresses, activate IGMP Snooping.
- Volume: adjust according to the number of sounders in the room and the size of the room. For
example, in an office set a lower (3 or 4) volume and in a refectory the highest (7 or 8) volume.
Boost
- Enable
checkbox: adds a few decibels to the selected volume level.
- N° zone: sets the address of the client or server repeater.
- Client/server repeater: in a complex network with one or more remote installations it may be
necessary to use network gateways.
To do this, we must define repeaters that will move information from one network to another.
On each pair, a sounder is defined as server and the other as a client.
It is recommended to place the server repeater in the network where the Sigma (and the
microphone) is located.
- Repeater address: used to enter the network address of the other sounder of the repeater pair.
The Save and Save and Reboot button saves your configuration and reboots the equipment.