8. OUTPUT EDIT MENU
To open the edit menu for the settings of an output, you have to press SHIFT + OUTPUTn,
OUTPUTn being the OUTPUT encoder corresponding to the desired output (ZONE A, B, C or D).
Once in the edit menu for an output, and in one of its pages, you can obtain the same page for
another output by pressing SHIFT + OUTPUTm, OUTPUTm being the encoder for the new targeted
output.
The new edited values are activated in real time. You can cancel an edit operation, returning the
value before editing, by pressing SHIFT + CANCEL.
To exit the Edit menu and return to the main screen:
Press SHIFT + EXIT
Press SHIFT + OUTPUTn (the encoder of the currently edited output)
Stay 2 minutes without operating any control on the front panel
The next page shows the full structure and options of the menu for setting outputs.
NOTES:
1. The crossover filter applied to each output can be of high-pass (HP) or low-pass (LP) type,
both with a Butterworth profile and a slope of 12 dB/octave, and a cut-off frequency adjustable
between 20 Hz and 20 kHz
2. The graphic equalizer applied to each output has a setting of ±10 dB for each of the 10
available bands:
31.5 Hz
63 Hz
125 Hz
250 Hz
500 Hz
1 kHz
2 kHz
4 kHz
8 kHz
16 kHz
3. The COPY FROM – PASTE TO operation copies all the settings from the source output to the
destination output, except for its name (LABEL)
4. The compressor available on each output behaves as a limiter when the compression RATIO is
inf:1.
24