Télécharger Imprimer la page

Beta 1498/50A Mode D'emploi page 12

Publicité

INSTRUCTIONS FOR USE
B) "Flash" supply and charging mode: "Amperage"
Preset supply current bands:
Flash 5A: supply current set to 5A
Flash 15A: supply current set to 15A
Flash 30A: supply current set to 30A
Flash 50A: supply current set to 50A
Preset charging bands to select the connected battery (output current adjusted automatically)
Charge 5 Ah - 50 Ah: Supports batteries from 5Ah to 50Ah.
Charge 50 Ah - 150 Ah: Supports batteries from 50Ah to 150Ah.
Charge 150Ah - 300 Ah: Supports batteries from 150Ah to 300Ah.
Charge 300Ah – 500Ah: Supports all batteries from a minimum of 300Ah to a maximum of 500Ah.
C) "Flash" supply voltage and supported batteries: "Volt / Batt."
Preset supply bands:
13.8V: Supply voltage set to 13.8V
14.4V: Supply voltage set to 14.4V
14.8V: Supply voltage set to 14.8V
Preset battery types:
Wet: Acid electrolyte batteries. Charge end at 14.4V
Agm: Agm batteries with flat plate or Optima type spiral cell. Charge end at 14.7V
Gel: Batteries with gelatinous electrolyte. Charge end at 14.2V
Saving Settings
The battery charger saves the settings made on the front control panel. In the event of an accidental power loss or voluntary
power off, when the charger is restarted, it will restart with the latest saved settings. With the battery charger set to the FLASH
mode, the work cycle will resume automatically when the power supply is restored. Whereas in the CHARGE mode, the screen
will display the message ER01, and the START/STOP key will have to be pressed, to resume the normal charge cycle.
Battery Analysis
The analysis stages within the operating modes may terminate with the signalling of some errors.
• Damaged Battery: the ''Fault'' LED switches on and the ''Start / Stop'' LED switches off, and the charger enters
Standy-by mode. The display shows the message ''Errx'' where 'x' is the number corresponding to the cause of the
error (see Table 1). Single two second audible warning.
• Polarity reversal: the ''Reverse'' LED switches on, and the display shows the message ''Err7'' with a two second
audible warning.
Error Codes
The errors that may be reported are described in Table 1.
Table 1: Numbering of errors
DISPLAY
INDICATION
E01
E02
12
CAUSE
Leads disconnected, leads short-
circuited.
Battery completely short-circuited.
Battery faulty or unrecoverable
No current accepted after 20 hours
of recovery
SOLUTION
Position the clamps correctly and start charging the battery
again (see section "Operating the Charger").
The battery could be defective. Contact your nearest battery
service centre.
The battery could be defective. Contact your nearest battery
service centre.
EN

Publicité

loading