Altrad Belle RPX 59/65 Manuel De L'opérateur page 12

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

GB
Hatz 1D50 Diesel Engine
Stopping the Engine
Starting the Engine
1. Turn ON the fuel by moving the fuel ON/OFF lever fully to the right.
2. Set the engine speed control to start.
hands.
Hatz 1D50 Diesel Engine (Electric Start)
Stopping the Engine
2. Turn the key to position '0' and remove it. All the indicator lights must go out.
NOTE:- Failure to return the starter key to position '0' may result in the battery being totally
discharged.
Starting the Engine
1. Insert the key and turn it to position 'I' (The battery charge light and oil pressure warning light
2. Turn start key to position 'II'
3. Release the key as soon as the engine runs. The starting key must spring back to position 'I'
and remain there during engine operation. The battery charge light and oil pressure warning
light must go out immediately after starting. Indicator light '1' lights up to show that the engine
is running.
Never operate the electric starter when the engine is running or coasting to a standstill. There is a risk of
broken starter pinion or ring gear teeth. Never stop the engine by moving the decopression lever.
CAUTION
During breaks in work or at the end of theworking period, keep the starting handle and starting key in a
safe place, out of reach of unauthorised persons.
5. Always turn the start key back to position '0' before re-starting the engine. The repeat lock prevents the starter motor from
engaging and possibly being damaged whilst the engine is still running.
Start And Stop Procedure
12
Fig.1
Fig.2
Fig.3

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Rpx 59/75

Table des Matières