Télécharger Imprimer la page

TERMA MEG Mode D'emploi page 17

Masquer les pouces Voir aussi pour MEG:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 38
and the heating element unit is tight.
8. Connect the device to electricity and turn on the
heating element unit (upper collector opening must
be open!).
WARNING! One can use a hot heating agent of
temperature not exceeding 65° C for filling the
radiator. In such case, fill the entire radiator, put
it in an upright position and turn the heating
element unit on.
9. Set the maximum possible temperature and observe
the liquid level rise — the excess liquid may be
slopping through the upper opening in the collector
— remove excess liquid in order not to allow for
the heating element control head to be flooded or
wetted.
10. When the level of the heating agent stops rising, wait
another 5 minutes, turn off the heating element unit
and disconnect the device from electricity.
11. Do not wait until the radiator cools down and pour
a small amount of the liquid out — to the mid level
of the top pipe.
12. Close the upper opening of the collector with the
dedicated seal and put it back on the wall.
13. Connect the heating element unit to the
socket / installation. The device is ready for use.
en
17

Publicité

loading

Ce manuel est également adapté pour:

MoaReg 2Reg 3