Intended use of device
Terma heating elements and control heads are electric
heating devices and are intended for installation and use
in radiators used for heating interior spaces or drying
towels or clothes. Heating element and control head can
be installed in a radiator connected to the central heat-
Technical information
Model code (power wire type)
Electric supply
Heating output available
Device protection class
Radiator connection
Casing protection mark [IP]
Electric connection type
* — with plug
** — without plug
Construction of the heating element unit
1.
Heating element
2.
Heating element head
3.
Control head
4.
Power wire
5.
Gasket
PB/PW/SW/SB
230 V / 50 Hz
120, 200, 300, 400, 600, 800, 1000 W
Class I
G 1/2"
IPx4: MEG, REG 2*, MOA
IPx5: REG 2**, REG 3
Y: MEG, REG 2*, MOA
Z: REG 2**, REG 3
or device permanently connected to power supply**
en
ing system for use during the heating season as well as in
an individual electric radiator.