Installation of the heating element unit — Electric radiator
 • Radiator powered by the heating element only, not
connected to the central heating system.
 • Water, water with anti-freezing agent or the right
type of oil should be used as a heating agent — po-
ssibility of installation and correct use is conditioned
by meeting manufacturer's requirements on the
radiator and heating element.
 • Filling the radiator with too much liquid leads to
exceeding of acceptable pressure and damaging of
the radiator or heating element. If You are filling the
radiator yourself, please act strictly according to the
below instructions.
 • Other methods of correct filling of radiator can be
found on www.termagroup.pl. Radiator should not
be filled with a heating agent of temperature higher
than 65° C.
 • Heating element should not be fitted horizontally or
turned downwards.
 • The device should not be twisted or untwisted being
held by the casing. Always use a spanner 22 for
fitting the unit!
WARNING! The device must not be con-
nected to electricity during installation.
Unplug the device prior to installation.
WARNING! Please take every precaution when
filling the radiator in order to avoid being burnt
by hot liquid.
16
User manual Meg, Moa, Reg 2, Reg 3 www.termagroup.pl
1. Insert heating element (1) into the threaded opening
at the bottom end of the collector.
2. Twist the head of the heating element with a spanner
no 22 until you feel resistance.
3. Refers to MEG/MOA: Special gasket (5) assures ti-
ghtness of connection and allows an additional twist
and correct positioning of the front of the control
head.
4. Put the radiator in an oblique position to make sure
that the upper collector opening is in the highest
point!!! The radiator must not be rested on the
heating element control head or any other part of
the heating element unit at any time!!!
5. Fill the radiator with the heating agent.
6. Put the radiator back in the upright position and
check the level of the liquid inside it.
7. Make sure that the connection between the radiator