ADVICE
PIPE SUPPORTS
All sanitary pipe work must be
supported, in accordance with the pipe
manufacturers recommendations, to
avoid dipping, which may cause the
build up of residual water and
subsequent blockage.
BENDS
Where possible long sweeping bends
should be used. Do not use short
straight elbows. If sweeping elbows
are not available, use two 45 degree
elbows back-to-back to make a 90
degree turn.
VERTICAL INSTALLATION FIRST
If vertical lift is required, this must
precede the horizontal pipe run.
The vertical discharge pipe should first
bypass the bowl, do not extend the
horizontal portion of the pipe for more
than 12-18 inches.
EASY ACCESS
The unit should be accessible and
removable in the event of maintenance
being required. During the installation a
full-port gate valve should be fitted at
the base of any vertical discharge pipe
work from the unit to allow easy
removal of the unit without flooding.
GRAVITY FALL
Horizontal discharge pipe work must
also have a positive gravity fall to allow
free drainage when the pump stops.
THREE FEET MINIMUM
The macerating/pump must have at
least 3 feet of total pipe run in between
the pump and soil stack.
This will cause the macerator to
operate for an adequate period of
time to ensure waste reduction.
SOIL STACK CONNECTION
This unit must discharge into a
minimum 3-inch sanitary drainage pipe.
All discharge pipe work must be
connected to the soil stack by an
appropriate and approved TY
connection. Please note: the use of a
Saddle Clip may be prohibited in your
area.
NO DIAGONAL "UPHILL" PIPE
RUNS
All discharge pipe work from the
unit should run either directly vertical
upwards from it or in a horizontal plane
(with a small gravity flow) to the point
of discharge. Pipe work should not be
installed with diagonal upward slope
from the unit.
PIPE WORK
All pipe work should be either copper
or solvent weld plastic (PVC, CPVC).
Do not us flexible pipes.
DISCHARGE
Never discharge directly into an open
drain, manhole or rainwater drain pipe.
It is illegal.
FREEZING
Ensure all pipe work susceptible
freezing is adequately insulated. The
toilet and macerating/pump unit must
be properly winterized in unheated
buildings.
ELECTRICITY
Before attempting any maintenance or
servicing, the unit must be disconnec-
ted from the power source.
The SANICOMPACT
®
must be
connected to a Ground Fault Circuit
Interrupter and be supplied with 120V,
60Hz.