Technical information / Operation / Parameters
Adjustable parameters
Configuration for output 1
2 switching functions are adjustable:
- Hno = hysteresis function / normally open
- Hnc = hysteresis function / normally closed
- Fno = window function / normally open
- Fnc = window function / normally closed
Switch point for hysteresis function OUT1
Limit value at which the output with selected hysteresis function
changes its switching state (object nearer/farther than distance
set).
SP1 is active only if OU1 = Hno or Hnc.
Switch points for window function OUT1
Limit value at which the output with selected window function
changes its switching state (object present / not present between
the distance "near" and the distance "far").
nSP1 = switch point "near" / FSP1 = switch point "far".
nSP1 / FSP1 are active only if OU1 = Fno or Fnc.
Configuration for output 2
4 switching functions and 2 analogue signals can be set:
- Hno = hysteresis function / normally open
- Hnc = hysteresis function / normally closed
- Fno = window function / normally open
- Fnc = window function / normally closed
- I = analogue output 4...20 mA
- U = analogue output 0...10 V
Switch point for hysteresis function OUT2
Limit value at which the output with selected hysteresis function
changes its switching state (object nearer/farther than distance
set).
SP2 is active only if OU1 = Hno or Hnc.
Switch points for window function OUT2
Limit value at which the output with selected window function
changes its switching state (object present / not present between
the distance "near" and the distance "far").
nSP2 = switch point "near" / FSP2 = switch point "far".
nSP2 / FSP2 are active only if OU2 = Fno or Fnc.
Analogue start point
Measured value at which 4 mA / 0 V is provided.
ASP is only active if OU2 = I or U.