Di-soric LHT 9-45 M 10 P3IU-B4 Notice De Montage page 28

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Analogue end point
Measured value at which 20 mA / 10 V is provided.
Minimum distance between ASP and AEP = 100 mm.
ASP is only active if OU2 = I or U.
The error message "SIZE" is displayed if you try to enter a dis-
tance which is below the minimum distance.
Teach
Selection "sampling rate" or "repeatability"
Setting ranges:
The sampling rate influences the accuracy and vice versa.
High sampling rate → low repeatability.
High repeatability → low sampling rate.
Extended functions
This menu point includes a submenu with more parameters.
Press the Set button briefly to access these parameters which
will be explained on the following pages.
Delay for the switching outputs
dSx = switch-on delay; drx = switch-off delay.
The output does not immediately change its switching status
when the switching condition is met but only after the delay has
elapsed. If the switching condition is no longer met after the
delay has elapsed, the switching status of the output does not
change.
• Setting range: 0 / 0.1...5 s in steps of 0.1 s
(0 = delay is not active).
• Indication in seconds.
dS2 and dr2 are not effective if OU2 = I.
Damping of the signal measured
This function allows to suppress short-time saturation of the
measuring element (such saturation may result from direct
reflection or strong fluctuations in brightness).
During the delay set, the latest valid value measured is dis-
played, the output signals remain unchanged.
• Setting range [s]: 0.0 - 0.1 - 0.2 - 0.5 - 1.0 - 2.0 - 5.0.
28
→ Sampling rate 1...33 Hz
→ Repeatability 1...100 mm

Publicité

Table des Matières
loading

Produits Connexes pour Di-soric LHT 9-45 M 10 P3IU-B4

Table des Matières