Set-Up / Operation - Di-soric LHT 9-45 M 10 P3-B4 Notice De Montage

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Programming failed:
The display indicates "FAIL".
• The measured value difference is too small, switch point not a
dopted.
Lock or unlock the buttons:
• Press the two buttons simultaneously for 10 s.
The display indicates "Loc" (buttons locked) or "uLoc" buttons not locked).

Set-up / Operation

After mounting, wiring and programming check whether the unit
operates correctly.
Life of the laser diode: 50 000 hours.
Faults displayed during operation:
++
too much light, e.g. reflective surfaces
--
not enough light
FAR
measured object outside the measuring range > 10 m
NEAR
measured object outside the measuring range < 0.2 m
SC
short circuit in the switching output
Repeatability and accuracy:
Distance [mm]
200...1000
1000...2000
2000...4000
4000...6000
6000...10000
Range on black (6 % remission) ≤ 4000 mm
The values apply at
- constant ambient conditions (23 °C / 960 hPa)
- extraneous light of max. 8 klx
- only after unit powered up for 10 minutes.
12
Repeatability
white
90% remission
18% remission
± 4 mm
± 5 mm
± 14 mm
± 16 mm
± 21 mm
± 25 mm
±41 mm
grey
90% remission
± 5 mm
± 14 mm
± 6 mm
± 15 mm
± 24 mm
± 31 mm
± 51 mm
Accuracy
white
grey
18% remission
± 15 mm
± 16 mm
± 26 mm
± 35 mm

Publicité

Table des Matières
loading

Table des Matières