Di-soric LHT 9-45 M 10 P3IU-B4 Notice De Montage page 34

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Table Repeatability and accuracy
(values for sampling rate 1 Hz):
Distance [mm]
200...1000
1000...2000
2000...4000
4000...6000
6000...10000
Range on black (6 % remission) ≤ 4000 mm
The values apply at
- constant ambient conditions (23 °C / 960 hPa)
- extraneous light of max. 8 klx
- only after unit powered up for 10 minutes.
Scaling of the measuring range (analogue output)
• With the parameter analogue start point (ASP) you define at which
measured value the output signal is 4 mA / 0 V.
• With the parameter analogue end point (AEP) you define at which
measured value the output signal is 20 mA / 10 V.
The analogue end point (AEP) can be selected so that it is located
before the analogue start point (ASP). This implements a falling edge.
Minimum distance between ASP and AEP = 100 mm
34
Repeatability
white
90 % remission
18 % remission
± 4.0 mm
± 4.5 mm
± 13.5 mm
± 14.0 mm
± 19.0 mm
± 21.0 mm
± 37.0 mm
grey
90 % remission
± 4.5 mm
± 14.0 mm
± 6.0 mm
± 15.0 mm
± 23.5 mm
± 29.0 mm
± 47.0 mm
Accuracy
white
grey
18 % remission
± 15.0 mm
± 16.0 mm
± 24.0 mm
± 31.0 mm

Publicité

Table des Matières
loading

Produits Connexes pour Di-soric LHT 9-45 M 10 P3IU-B4

Table des Matières