Di-soric LHT 9-45 M 10 P3IU-B4 Notice De Montage page 29

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Display setting
7 settings can be selected:
d1
= update of the measured value every 50 ms
d2
= update of the measured value every 200 ms
d3
= update of the measured value every 600 ms
The update of the measured value only refers to the display. It
has no effect on the outputs.
rd1, rd2, rd3 = display like d1, d2, d3, but rotated by 180°.
OFF = The measured value display is deactivated in the Run
mode.
Press one of the buttons to indicate the current measured value
for 15 s. If the Mode/Enter button is pressed once again, the dis-
play mode is activated. The LEDs remain active even if the display
is deactivated.
Display unit
Measured value and values for SP1, SP2, ASP, AEP can be indicat-
ed in the following units:
• mm, m, inch
Select the display unit before you define the values for the para-
meters SPx, nSPx, FSPx, ASP, AEP. This avoids rounding errors
during internal conversion to other units and enables exact set-
ting of the values.
When delivered: mm, the selected unit is indicated by a green
LED on the display.
Restore basic settings (factory settings)
- Press [Mode/Enter] until "rES" is displayed.
- Press [Set] and keep it pressed until "- - - -" is displayed.
- Press [Mode/Enter] briefly
(→ the unit passes into the Run mode).
The unit is delivered with the following factory settings:
• Uni = mm
• OU1 = Hno; OU2 = I
• SP1 = 1000 mm; nSP1 = 800 mm; FSP1 = 1200 mm
• SP2 = 2000 mm; nSP2 = 1800 mm; FSP2 = 2200 mm
• ASP = 0 mm; AEP = 9999 mm
• Sampling rate = 15 Hz
• dS1 = 0.0 s; dr1= 0.0 s; dS2 = 0.0 s; dr2 = 0.0 s
• dAP = 0.0 s
• dis = d3
Display of the software version number
29

Publicité

Table des Matières
loading

Produits Connexes pour Di-soric LHT 9-45 M 10 P3IU-B4

Table des Matières