h. Alarm detection response time
•
The default zone response time is set to 500ms. This setting can be adjusted independently per
zone, depending on the conditions in that zone.
The 8 digit code represents the 8 protection zones. The first digit is zone 1 and the last digit is
•
zone 8. By putting the timing codes into the specific digit to independently the desired response
time can be set.
15yyyyyyyy#
15
yyyyyyyy =
# =
i. Reset system to default
To reset the system to its default values, enter code 2100#.
•
Except for the master code, all other values will be cleared or set to their default.
•
j.
Exit programming mode
To leave programming mode, type
•
5.6
Operation
This system is designed with "FORCED TO ARM" operation. If faulty zones exist it will bypass the
faulty zones automatically after it is armed. The LED of the faulty zones will flash to indicate that
they are not protected and the "FORCED TO ARM" LED will also flash to indicate that the system is in
"Forced To Arm"-mode with the faulty zones bypassed.
a. Arm the system with exit delay
Make sure that the alarm system is in disarmed mode and the alarm memory is empty. If the
•
memory is not empty, clear it first (see below).
Enter an appropriate USER CODE and validate with
•
2-beeps confirm correct code entry, exit delay starts and EXIT/ARMED LED flashes.
•
5-beeps indicate incorrect code entry. Enter the code again.
•
System will arm after exit delay expires. The appropriate partition LED and the EXIT/ARMED LED
•
are ON.
b. Arm the system instantly
•
Make sure that the alarm system is in disarmed mode and the alarm memory is empty. If the
memory is not empty, clear it first (see below).
Enter an appropriate USER CODE,
•
•
2-beeps confirm correct code entry and the system arms instantly without exit delay. The
appropriate partition LED and the EXIT/ARMED LED are ON.
5-beeps indicate incorrect code entry. Enter the code again.
•
Note: as there is no exit delay, walking through the protected area will trigger the alarm. Mount
the keypad outside the protected zone to use this function.
c. Arm the system in home mode with exit delay
This function only works with USER CODE 3. The protection zones that are stored in memory will
•
be bypassed when arming.
Enter USER CODE 3,
•
2-beeps confirm correct code entry, exit delay starts and EXIT/ARMED LED flashes.
•
•
5-beeps indicate incorrect code entry. Enter the code again.
The LEDs indicating the bypassed zones will flash constantly.
•
System will arm after exit delay expires. The appropriate partition LED and the EXIT/ARMED LED
•
are ON.
Note: in HOME mode, USER CODE 1 and 2 can still be used to disarm the partitions.
d. Arm the system in home mode instantly
04 (21/08/2014)
HAM263D
master code
8 digits, default setting = 3
1
25 ms
2
250 ms
3
500 ms
4
750 ms
validation
.
,
and
The bypassed zones are not monitored and will not trigger alarms.
and
.
16
key.
.
VELLEMAN