en
ENGLISH
10.5 Water sensor
IMPORTANT - Clean the water
sensor regularly and check it for
signs of damage.
10.6 Technical inspection for ASR 35 M ACP,
ASR 35 H ACP
At least once a year, the manufacturer or a suitably
qualified and trained person must carry out a dust
test, e.g. to check for damage to the filter, verify that
the device is air-tight and that the control unit is
functioning correctly.
For maintenance by the user, the vacuum cleaner
must be taken apart, cleaned and maintained, to the
extent possible, without endangering maintenance
staff or other people.
Preventive measures
Appropriate preventive measures include: cleaning
the device before disassembly; providing local
filtered forced ventilation where the vacuum cleaner
is disassembled; cleaning of the maintenance area
and providing suitable personal protective clothing
and equipment.
When carrying out maintenance or repairs, it is
essential to dispose of any contaminated objects
that cannot be adequately cleaned. These objects
must be disposed of using impermeable bags and
in accordance with the applicable regulations for
removing such waste.
ANMERKUNG: In addition, the efficiency of the
vacuum cleaner should be checked on an annual
basis for class H vacuum cleaners.
11. Troubleshooting
If the volume flow control display (3) lights up or if an
acoustic signal is sounded (only for ASR 35 M ACP,
ASR 35 H ACP), this indicates that the fleece filter
bag must be emptied.
Reduction in suction power:
See the instructions in the section on Cleaning.
• Filter cassettes (17) soiled? - clean.
• Fleece filter bag (7) full? - replace.
• PE disposal bag (6) full? - replace.
• Container (10) full? - empty.
• Motor protection filter (16) clogged? - See
chapter 10..
• Nozzle, tubes or hose blocked?- clean.
Device will not start:
• Is the plug in the plug socket?
• No power from mains?
• Mains lead OK?
• Device hood correctly closed?
• Has the water sensor cut off? - Empty the
container; then switch on and off again.
• Switch (2) in "AR" position? - Set to "I" or "IR".
See chapter 7.1.
• The vacuum cleaner is not switched on or off by
means of a power tool, even though switch (2) is
22
set to the "AR" position. - Connect the power tool
to the plug socket (4) .
Dust in the container when fleece filter bag is
fitted:
• The position of the rotary slide is incorrect. See
chapter 6.2.
PE disposal bag is sucked to the filter
cassettes (17):
• The position of the rotary slide is incorrect. See
chapter 6.3.
PE disposal bag is sucked to the filter
cassettes (17):
• The position of the rotary slide is incorrect. See
chapter 6.3.
Do not interfere with the device. Contact
an authorized workshop or Metabo's after-
sales service department (see chapter 13. on
Repairs).
f
12. Accessories
Use only genuine Metabo accessories.
If you need any accessories, check with your
dealer.
See page 4.
19 Fleece filter bag (for class L and M devices)
5 pieces = 1 set
20 PE disposal bag (for class L, M and H devices)
5 pieces = 1 set
21 Paper filter cassette (for class L and M devices)
2 pieces = 1 set
22 Polyester filter cassette (for class L and M
devices)
2 pieces = 1 set
23 Polyester Nano filter cassette (for class L and M
devices)
2 pieces = 1 set
24 HEPA filter cassette (for class H devices)
2 pieces = 1 set
25 Motor protection filter (1 filter) You must order 2
items.
26 Handle
27 Cable clips (10 clips)
28 Suction hose
29 Suction tubes (2 items)
30 Intermediate piece
31 Suction nozzle
32 Floor nozzle (metal fitting)
33 Universal nozzle
34 Universal brush
35 Upholstery brush
36 Crevice nozzle
37 Rubber nozzle
38 Floor nozzle set (with floor piece and wet
vacuuming piece)
39 Multi-purpose nozzle
40 Power tools suction set
41 Suction hose
42 Suction hose (antistatic)
43 Adapter