MODBUS data description
Identification and counters
Block 0: Model, release sw, work. hour and maintenance
Addr
Type
Size
0x0000
char[10]
10
0x0005
byte[10]
10
0x000A
word
2
0x000B
word
2
0x000C
word
2
0x000D
word
2
0x000E
ulong
4
0x0010
ulong
4
0x0012
ulong
4
0x0014
ulong
4
0x0016
ulong
4
0x0018
ulong
4
0x001A
ulong
4
Parameters
Block 1: General
Addr
Type
Size Name
0x0100
word
2
P01
0x0101
word
2
P02
0x0102
word
2
P03
0x0103
long
4
DummyA
0x0105
long
4
DummyB
0x0107
long
4
DummyC
0x0109
word
2
P04
0x010A
word
2
P05
0x010B
word
2
P09
0x010C
word
2
P06
0x010D
word
2
P08
0x010E
word
2
P10
0x010F
word
2
DUMMY1
0x0110
char[10]
10
MATRICOLA
0x0115
int
2
P07
Name
Notes
MATRICOLA
Serial number (ref. to menu 10)
DUMMY0
Not used
MODEL
For Sentinel Pro returned data is 0x6000
This data is useful to identificate possible variation or future hardware personalization.
SWREL
Firmware release for I/O board
MSB = major release
LSB= minor release
PROTREL
Reported description refers to returned data 0x0000
This is useful to handle possible future modification in MODBUS data description
which requires a different interpretation for data themselves.
SWRELFRONT
Firmware release for front panel
MSB = major release
LSB= minor release
S0
Operating hours [h]
S1
Oil change counter [h]
S2
Oil filter counter [h]
S3
Air fileter counter [h]
S4
Belt replacement counter [h]
S5
Bearing replacement counter [h]
S6
Compressor overhaul counter [h]
Notes
Language set-up (ref. to menu 5.2.3.3):
0=Italian,
1=Francais,
2=English
3=German
4=Spanish
5=Portoguese
Visualisation mode set-up (ref. to menu 5.2.3.3):
0=S.I.(mbar,bar,C°)
1=USA(Hg,psi,F°)
Legal time automatic selection (ref. to menu 5.2.3.3):
0=Solar time
1=Legal time
Not used
Not used
Not used
Oil level kit (ref. to menu 5.2.3.9):
0=IN5 e IN6 are not active
1=Only IN5is active
2=Both IN5 e IN6 are active
Compressor overhaul (ref. to menu 5.2.3.9), handling of parameter 6-M6 and the related
maintenance alarm.:
0=NO
1=YES
Lubrication (ref. to menu 5.2.3.9):
0=forced lubrication
1=splash lubrication
2=blower
Fan motor OFF Timer [min] (ref. to menu 5.2.3. 9)
Oil level alarm delay [s] (ref. to menu 5.2.3.9)
Operation type (vedi menu 5.2.3.9):
0=Pressure
1=Vacuum
Not used
Sentinel Serial number (ref. menu 5.2.3.10)
Offset PWM [V*100] (ref. menu 5.2.3.9)