Fault diagnosis

16 Fault diagnosis

16.1 Fault rectification

Fault
Urinal not flushing
S. 74
Possible cause
No power supply
No water supply
Fault rectification
Make sure that the battery
compartment / power supply unit
is connected to the controller.
Check the connection between
the power supply unit and the
domestic power connection.
Check cable connection.
Check battery (diagnostics mode,
see "Diagnosis & user statistics",
page
70).
Check battery (diagnostics
mode, see separate operating
instructions).
Open the stop cock on the water
supply line.
Make sure that the solenoid valve
is connected to the controller.
Check the functioning of the
solenoid valve (diagnostics mode,
see "Diagnosis & user statistics",
page 70
or check via app).
Check the functioning of the
solenoid valve (diagnostics mode,
see separate operating instructions
or check via app).