Télécharger Imprimer la page

Pontec PondoSolar 150 Notice D'emploi page 7

Masquer les pouces Voir aussi pour PondoSolar 150:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 9
Safe operation
• Do not carry or pull the unit by its electrical cable.
• Route cables/hoses such that they are protected from damage and do not present a tripping hazard.
• Only use original spare parts and accessories for the unit.
• In the case of electrical units and installations with a rated voltage of U > 12 V AC or U >30 V DC located in the wa-
ter: Isolate the units and installations (switch off and disconnect from the power supply) before reaching into the wa-
ter.
• Only operate the pump together with the supplied solar module.
• Do not allow the pump to run dry.
• Protect the unit from knocks or vibration.
• Clean the unit at least twice a year.
• Keep the connection plugs dry.
Installation and connection
How to proceed:
B
1. Assemble the nozzle unit and fit onto the pump.
– Adapt the number of nozzle extensions used to the depth of the pond.
2. Set the desired pump flow rate.
– To increase: Turn the control knob counterclockwise.
– To reduce: Turn the control knob clockwise.
– Recommendation: The maximum flow rate is the optimum setting for the fountain display. For this, turn the con-
trol knob counterclockwise.
3. Connect the connection cable to the solar module.
– Push the plug completely into the socket (up to the stop) to ensure that the connection is watertight.
– Switching on: Connect the pump to the solar module.
– Switching off: Disconnect the solar module from the pump.
4. Assemble the ground stake set and attach it to the solar module.
– Ensure that the connection cable is routed downwards.
5. Fix the pump underwater to a smooth, clean surface using the suction cups.
6. Install the solar module so that it is exposed to direct sunlight.
– Recommendation: Align the solar module to the sun to ensure maximum energy yield.
Remedy of faults
Malfunction
Pump does not start.
Insufficient or no pump delivery.
40684-11-14_GA_PondoSolar-150.pd7 7
Cause
No connection to the solar module.
The solar module is soiled.
The impeller unit is blocked
The filter is clogged.
The nozzle unit is clogged.
The impeller unit is worn.
Insufficient sunlight
- GB -
Remedy
Connect the pump to the solar module.
Correctly insert the connection cable.
Clean
Clean
Open the pump, remove and clean the filter.
Remove and clean the nozzle unit.
Replace
Direct sunlight
03.11.2014 10:28:48
7

Publicité

loading