Assembly
1. Attach the carrying strap [3] to the tank. (Fig. 2)
2. Screw the spray lance [2] onto the shut-off valve [6]. (Fig. 3)
Checks
Visual inspection:
valve [6] with spray line, pressure gage [11] and spray lance [2] with nozzle undamaged?
+
Pay special attention to the connections between the pressure vessel - spray line and the
spray line – shut-off valve and to the condition of the spray lance.
Function: Activate the pump lever [10]. (Fig. 7)
► Increasing pressure is indicated on the pressure gage [11].
+
The wheel lock [12] can be used to lock and unlock the lever on the shut-off valve [6].
Locking the lever [12b] prevents unintentional spraying.
Unlock the wheel lock [12a] and activate the shut-off valve [6]. (Fig. 8)
► The shut-off valve must open and close.
Have damaged parts or parts that do not work properly repaired immediately by
our customer service department or by service partners authorized by us.

Making preparations

Observe the instructions in the section entitled "Safety".
The device must be in an upright position.
If filling the tank from a water line, ensure that the line or a hose does not project
into the tank.
1. Screw the cover [7] off the tank. (Fig. 4)
+
We recommend you mix the spraying liquid in the device or premix it in an external tank:
Fill to 1/3 with water, pour in the spraying agent, and then add more water until full.
2. Pour the spray liquid through the filling strainer [8] into the tank. (Fig. 5)
3. Screw the cover [7] onto the tank. (Fig. 6)
Spraying
Observe the instructions in the section entitled "Safety".
Operate the device only while it is vertical or suspended upright and nearly verti-
cal.
Avoid allowing drops of spray to drift onto areas that are not being treated.
Observe the instructions of the spray product manufacturer!
1. Place the device on its back. (Fig. 7)
2. Using the pump lever [10], pump slowly and regularly to maintain a continuous
spraying pressure. (→ Table 2, Fig. 7)
+
The maximum pressure should not exceed 6 bar. If the max. pressure is exceeded,
the function may be affected.
+
To prevent dripping, hold the spray lance up when first spraying and activate the
shut-off valve until no more liquid mixed with air is emerging.
3. Activate the shut-off valve [6]. (Fig. 8)
► Spraying may now begin.
4. Ensure that the optimum spraying pressure (→ Table 2) is set on the pressure
gage [11] (Fig. 8).