SLG−...
11
Technical specifications
Type
Mounting position
Design
Medium
Stroke range
End position cushioning
Operating pressure
Permitted temperature
range
Slide speeds
Minimum speed of shock
absorber type YSRG−...
Theoretical effective power
Theoretical air consump
tion
Leakage when new
Permitted loading of outer
slide
Permitted torques on outer
slide
Weight forces (P/YSRG)
Festo SLG−... 0802d English
SLG−8−...
As desired
Double−acting pneumatic cylinder without piston rod
Compressed air: filtered, dried, lubricated or non−lu
bricated
Can be shortened as desired
Elastic or hydraulic cushioning
min.
2.5 bar
max.
8 bar
− 10 °C ... + 60 °C
min.
0.3 m/s
max.
1 m/s
0.05 m/s
at 6 bar
30 N
at 6 bar
0.0035 Nl
at 6 bar
10 Nl
Fg, Fl
255 N
Longitudinal:
3.5 Nm
Ml, Mv
Lateral: Mq
1 Nm
Adapter plate
65 g
Slide
80 g/90 g
SLG−12−...
SLG−18−...
2 bar
1 bar
8 bar
8 bar
0.2 m/s
0.1 m/s
1 m/s
1.5 m/s
68 N
153 N
0.0079 Nl
0.018 Nl
10 Nl
10 Nl
565 N
930 N
9 Nm
23 Nm
3 Nm
7 Nm
65 g
105 g
160 g/170 g
440 g/470 g