Drain System; Electrical Requirements - 240 Volt Models - Kenmore 110.81422 Guide D'utilisation Et D'entretien

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Mobile Home – Additional Installation Requirements
This Laundry Center is suitable for mobile home installations. The
installation must conform to the Manufactured Home Construction
and Safety Standard, Title 24 CFR, Part 3280 (formerly the
Federal Standard for Mobile Home Construction and Safety,
Title 24, HUD Part 280) or the Canadian Manufactured Home
Mobile home installations require:
Metal exhaust system hardware, which is available for
I
purchase from your local Sears store or Sears Service Center.
Special provisions must be made in mobile homes to introduce
I
outside air into the dryer. The opening (such as a nearby
window) should be at least twice as large as the dryer exhaust
opening.

DRAIN SYSTEM

The Laundry Center can be installed using the standpipe drain
drain system. Select the drain hose installation method you need.
See "Alternate Parts".
The standpipe drain requires a minimum diameter standpipe of 2"
17 gal. (64 L) per minute. A 2" (51 mm) diameter to 1" (25 mm)
diameter standpipe adapter kit is available. See "Alternate Parts".
The top of the standpipe must be at least 39" (991 mm) high and
no higher than 96" (2.4 m) from the bottom of the washer.
A
Laundry tub drain system (view C)
The laundry tub needs a minimum 20 gal. (76 L) capacity. The top
and no higher than 96" (2.4 m) from the bottom of the washer.
Floor drain system (view D)
purchased separately. See "Alternate Parts".
The siphon break must be a minimum of 28" (710 mm) from
the bottom of the washer. Additional hoses might be needed.
C
C
39"
(991 mm)
B
34"
(864 mm)
ELECTRICAL REQUIREMENTS – 240 VOLT MODELS
(U.S.A.)
It is your responsibility
I
To be sure that the electrical connection is adequate and in
I
conformance with the National Electrical Code, ANSI/NFPA
National Fire Protection Association, One Batterymarch Park,
Quincy, MA 02269.
To supply the required 3 or 4 wire, single phase, 240 volt, 60
I
Hz., AC only electrical supply (or 3 or 4 wire, 208 volt electrical
or circuit breaker is recommended. Connect to an individual
branch circuit. Do not have a fuse in the neutral or grounding
circuit.
Do not use an extension cord.
I
If codes permit and a separate ground wire is used, it is
I
ground path is adequate.
Electrical Connection
To properly install your Laundry Center, you must determine the
type of electrical connection you will be using and follow the
instructions provided for it here.
I
electrical supply connection. The neutral ground wire is
permanently connected to the neutral conductor (white wire)
supply connection, the neutral ground wire must be removed
from the internal ground connector (green screw), and secured
under the neutral terminal (center or white wire) of the terminal
block. When the neutral ground wire is secured under the
neutral terminal (center or white wire) of the terminal block,
the dryer cabinet is isolated from the neutral conductor.
If local codes do not permit the connection of a neutral ground
I
"Electrical Connection" section.
I
a mobile home or an area where local codes do not permit
grounding through the neutral.
If using a power supply cord:
Use a UL listed power supply cord kit marked for use with
I
I
minimum. The cord should be type SRD or SRDT and be at least
4 ft (1.22 m) long. The wires that connect to the dryer must end
in ring terminals or spade terminals with upturned ends.
A UL listed strain relief.
I
If your outlet looks like this:
receptacle
D
D
ring or spade terminals and UL listed strain
conductor) may be either green or bare. The
cover.
7