DRAIN SYSTEM

Drain system can be installed using a floor drain, wall standpipe,
floor standpipe, or laundry tub. Select method you need.
Floor standpipe drain system
4.5"
(114 mm)
Minimum diameter for a standpipe drain: 2" (51 mm). Minimum
carry-away capacity: 17 gal. (64 L) per minute. Top of standpipe
must be at least 39" (990 mm) high; install no higher than 96"
(2.44 m) from bottom of washer. If you must install higher than
96" (2.44 m), you will need a sump pump system.
Wall standpipe drain system
4.5"
(114 mm)
See requirements for floor standpipe drain system.
Floor drain system
Floor drain system requires a Siphon Break Kit (Part Number
285834), 2 Connector Kits (Part Number 285835), and an
Extension Drain Hose (Part Number 285863) that may be
purchased separately. To order, please see toll-free phone
numbers in your Use and Care Guide. Minimum siphon break:
28" (710 mm) from bottom of washer. (Additional hoses may
be needed.)
Laundry tub drain system
4.5"
(114 mm)
(990 mm)
Minimum capacity: 20 gal. (76 L). Top of laundry tub must be at
least 39" (990 mm) above floor; install no higher than 96" (2.44 m)
from bottom of washer.
IMPORTANT: To avoid siphoning, no more than 4.5" (114 mm)
of drain hose should be inside standpipe or below the top of
wash tub. Secure drain hose with beaded tie strap.
4
39"
(990 mm)
39"

ELECTRICAL REQUIREMENTS

A 120 volt, 60 Hz., AC only, 15- or 20-amp, fused electrical supply
n
is required. A time-delay fuse or circuit breaker is recommended.
It is recommended that a separate circuit breaker serving only this
appliance be provided.
This washer is equipped with a power supply cord having
n
a 3 prong grounding plug.
To minimize possible shock hazard, the cord must be plugged
n
into a mating, 3 prong, grounding-type outlet, grounded in
accordance with local codes and ordinances. If a mating outlet
is not available, it is the personal responsibility and obligation
of the customer to have the properly grounded outlet installed
by a qualified electrician.
If codes permit and a separate ground wire is used, it is
n
recommended that a qualified electrician determine that
the ground path is adequate.
Do not ground to a gas pipe.
n
Check with a qualified electrician if you are not sure the
n
washer is properly grounded.
Do not have a fuse in the neutral or ground circuit.
n

Publicité