ALTERNATE PARTS

Parts listed are available from your local Sears store or
Sears Service Center. For further information, please call
1-800-4-MY-HOME
®
(1-800-469-4663).
If you have:
Laundry tub or
standpipe taller than
96" (2.4 m)
1" (25 mm)
diameter standpipe
Overhead sewer
Floor drain
Drain hose too short
Lint clogged drain
beyond reach

LOCATION REQUIREMENTS

You will need
A location that allows for proper exhaust installation. See
I
"Venting Requirements".
I
If using a power supply cord on 240 volt models, and for 120
I
volt models, a grounded electrical outlet located within 2 ft.
(610 mm) of either side of the Laundry Center. See "Electrical
Requirements".
I
Center, water, and load) of 500 lbs (226.8 kg).
I
entire Laundry Center. Clothes may not tumble properly and
automatic sensor cycles may not operate correctly if Laundry
Center is not level. Installing on carpet is not recommended.
A water heater set to deliver 120°F (49°C) water to the washer.
I
Hot and cold water faucets located within 4 ft (1.2 m) of the
I
The Laundry Center must not be installed or stored in an area
where it will be exposed to water and/or weather.
6
You will need to buy:
Sump pump system (if not already
available)
2" (51 mm) diameter to 1" (25 mm)
diameter standpipe adapter,
Part Number 3363920
Standard 20 gal. (76 L) 34" (864 mm)
tall drain tub or utility sink and sump
pump (available from local plumbing
suppliers)
Siphon break, Part Number 285320,
additional drain hose, Part Number
285702, and connector kit, Part
Number 285442
Drain hose, Part Number 285664
and connector kit, Part Number 285442
Drain protector, Part Number 367031
6 ft (1.8 m), Part Number 76314,
Do not operate your washer in temperatures at or below 32ºF
(0ºC). Some water can remain in the washer and can cause
damage in low temperatures. See "Vacation, Storage, and Moving
Care" for winterizing information.
Do not operate your dryer at temperatures below 45°F (7°C). At
automatic cycle. This can result in longer drying times.
Check code requirements. Some codes limit, or do not permit,
installation of the Laundry Center in garages, closets, mobile
homes, or sleeping quarters. Contact your local building inspector.

Installation Clearances

The location must be large enough to allow the dryer door
to open fully.
Laundry Center Dimensions
71 ¾"
(1.82 m)
*27 ¼"
(692 mm)
** Most installations require a minimum 5" (127 mm) clearance behind
the dryer for the exhaust vent with elbow. See "Venting Requirements".
Minimum spacing for recessed area or closet installation
The following spacing dimensions are recommended for this
Laundry Center. This Laundry Center has been tested for spacing
of 0" (0 mm) clearance on the sides, rear, and top. Recommended
Additional spacing should be considered for ease of installation
I
and servicing.
Additional clearances might be required for wall, door, and
I
Additional spacing on all sides of the Laundry Center is
I
recommended to reduce noise transfer.
For closet installation, with a door, minimum ventilation openings
I
in the top and bottom of the door are required. Louvered doors
with equivalent ventilation openings are acceptable.
1"
23
/
"
1"
7
8
(25 mm)
(606 mm)
(25 mm)
(25 mm)
A
A. Recessed area
B. Side view – closet or confined area
C. Closet door with vents
** Required spacing
** Rear clearance may be 0" (0 mm) when house exhaust system
is lined up directly with dryer exhaust.
15
/
"
3
8
(390 mm)
32
/
"
1
8
(816 mm)
*23
/
"
7
8
(606 mm)
12"
(305 mm)
2
48 in.
2
(310 cm
)
24 in.
2
(155 cm
2
)
1"*
5"**
27 ¼"
(127 mm)
(692 mm)
B
C
3" (76 mm)
3" (76 mm)