11. Specifications

Measuring insert
Versions
Optimal heat transfer
Insertion length
Spring travel
Spring-loaded plate
Self-gripping spring

Operating conditions

Ambient and storage temperature
Vibration resistance
Standard
Option
20
Vibration-resistant, sheathed measuring cable (MI cable)
Requirement
Correct measuring insert length
Correct measuring insert diameter
Bore diameter of
Max. 1 mm [0.04 in] larger than measuring insert diameter
the thermowell
Joint width
For joint width > 0.5 mm [> 0.02 in] between thermowell
and measuring insert:
→ Negative impact on heat transfer
→ Unfavourable response behaviour of the thermometer
When fitting the measuring insert into a thermowell, it is very important
to determine the correct insertion length (= thermowell length for bottom
thicknesses of ≤ 5.5 mm [≤ 0.22 in]). In order to ensure that the measuring
insert is firmly pressed down onto the bottom of the thermowell, the insert
must be spring-loaded (spring travel: 0 ... 10 mm [0 ... 0.39 in]).
max. 10 mm [0.39 in]
max. 20 mm [0.79 in]
-40 ... +80 °C [-40 ... +176 °F]
The information on vibration resistance refers to the tip of the
measuring insert.
→ For detailed specifications on the vibration resistance of Pt100
sensors, see Technical information IN 00.17 at www.wika.de.
6 g peak-to-peak, wire-wound measuring resistor or thin film
Vibration-resistant probe tip, max. 20 g peak-to-peak, thin-film
measuring resistor
Highly vibration-resistant probe tip, max. 50 g peak-to-peak,
thin-film measuring resistor