materials. In this case the guarantee on the appliance lapses. Paper and carton must be used only
for ignition.
The combustion of wastes is forbidden by national law on the protection against emissions. This may
damage the stove and the chimney, causing health damages and claims by the neighbourhood owing to
the bad smell.
The wood is not a fuel which allows a continuous operation of the appliance, as consequence the heating
all over the night is not possible.
variety
Beech
Oak
Elm
Poplar
Larch*
Spruce*
Scots pine *
ATTENTION: the continuous and protracted use of aromatic wood (eucalyptus, myrtle etc.) quickly
damages the cast iron parts (cleavage) of the product.
8.
AIR ENTRANCE INTO THE INSTALLATION PLACE DURING THE COMBUSTION
As the stoves take their combustion air from the installation place, it is essential that a sufficient quantity of
air is introduced in the installation room itself.
In case of tight doors and windows (for example houses built according to the energy saving criteria) it is
possible that the air entrance is not guaranteed, compromising the draught, the welfare and the security of
the people. It is necessary to guarantee a further air entrance through a external air intake, to be positioned
in the nearby of the appliance or through air connection towards outside or a near ventilated room, with
the exception of thermal units place or garages (FORBIDDEN).
The stove, on the back of its pedestal, is endowed with a junction (d. 120 mm
Picture 9 pos. A) which is to be connected with a flexible pipe for the external air intake. The connection
pipe must be flat with a minimum diameter of 120 mm, a maximum length of 4 m and with no more than 3
bends. If there is a direct connection with the outside it must be endowed with a special windbreak.
The air entrance for combustion into the installation place must not be closed during the operation of the
stove. It is absolutely necessary that in the environment in which the stoves operate with the natural flue of
the chimney, it is introduced as much air as necessary for the combustion, i.e. up to 20 m
The natural recirculation of air must be ensured by some fixed openings on the outside. The size of the
necessary openings for air is fixed by the relevant prescriptions. Ask information to your chimney sweeper.
The openings should be protected with grids and should never be obstructed.
An extraction hood (aspirating) installed in the same room or in a room nearby, causes depression with
output of combusted gasses (smoke, smell). As consequence it is necessary to ensure more flow of fresh
air.
The depression in an extraction hood can at worst
hypothesis, transforms the flue into an external air intake, by
sucking
the
smokes
consequences for the people.
9.
LIGHTING
IMPORTANT: the first time that the appliance is lit, there will be
an odour given off (due to the drying of the adhesives of the
junction chord), which disappears after a short use. It must be
ensured, in any case, a good ventilation of the environment.
22
Kg/mc
750
900
640
470
660
450
550
*Resinous wood not suitable for the burning
of
the
rooms
with
KWh/Kg moistness 20%
dangerous
Picture 9
FIREBALL
4,0
4,2
4,1
4,1
4,4
4,5
4,4
/hour.
3
A