FIREBALL
The heating of the environment is made by irradiation: through the panoramic glass and the external hot
surfaces of the stove, the heat is radiated into the environment.
The stove is equipped with controls of primary and secondary air by which it is adjusted the combustion air.
1 - PRIMARY air register (left lever)
Below the hearth door, on the front left side, there
is the primary air register, in the style of lever
(Picture 1 - 1)
With this air register, it is adjusted the passage of
primary air into the low part of the stove and
through particular channels flows in the fuel
direction. The primary air is necessary for the
combustion process during lighting. The ash
drawer must be regularly emptied, so that the ash
does not obstruct the entry of the primary air for
the combustion. In order to open the air flow, the
bar must be completely pulled out,
During wood combustion, the register of primary
air must be opened only for a while, because
otherwise the wood burns too fast and the stove
may overheat.
(see paragraph 10).
2 - SECONDARY air register (right lever)
Below the hearth door, on the right front side there is the secondary air register (Picture 1 - 2).
The secondary air, passing through the two lateral jambs of the front side, heats itself starting the double
combustion and keeping at the same time the glass clean ( with open register).
When the bar is pushed to the back the passage of the secondary is completely open (Picture 1 - 2).
3.
RULES FOR INSTALLATION
The stove, assembled and ready for the installation, must be connected with a junction to the existing flue
of the house. The junction must be possibly short, straight, horizontal or positioned a little uphill. The
connections must be tight.
It is obligatory to respect the National and European rules, local regulations concerning building
matter and also fireproof rules. Please apply to your chimney sweeper for all information.
You should verify the sufficient air entrance for the combustion in the installation place, with particular
attention to windows and doors with tight closing (seal ropes).
It is not allowed the connection of various appliances to the same chimney. The diameter of the opening for
the connection must correspond at least to the diameter of the smokes pipe. The opening should be
equipped with a wall connection for the reception of the exhaust pipe and a rose window.
Before installation, verify if your floor can support the weight of the stove (for ex. distributing weight plate).
Please do not install the stove in a inclined level in order to avoid tensions during the rotation.
LA NORDICA is not responsible in case of modification of the product and for the use of not
original spare parts. The hearths must not be modified. THE HEARTHS MUST NOT BE MODIFIED.
3.1. CLEAN AIR ACT RESTRICTOR KIT – DEFRA – (ONLY FOR UK
SMOKE CONTROL AREAS)
To comply with the requirements of the United Kingdom Clean Air
Act, for use of appliances in smoke control areas, a permanent stop
(SF07224) must be fitted to prevent closure of the secondary air
control beyond 40%. This should be fitted as shown in Picture 2.
7196801 Rev.07 – EN
1
A
2
Picture 1
Picture 2