Scheduling
Heating or cooling schedule programming
Schedule programming allows you to
heat or cool the room in relation to
your preferences. Press OK to set hea-
ting or cooling schedule programming.
Turn the knob and select
- Complete menu
Press the OK button. Turn the knob and
select:
- CH or Cooling settings
Press the OK button. The display screen
shows:
- CH or Cooling Setpoint temp
- Time program
- Holiday function (in heating
mode only)
- Thermoregulation
Turn the knob and select:
- Time program
Press the OK button. The display screen
shows:
- Free time programming
- Wizard tme programming
- Preset programs
- Time Programming/manual mode
Turn the knob and select:
- Free time programming
Press the OK button. The display screen
shows:
- All zones
- Zone 1
- Zone 2
- Zone 3
Turn the knob and select the zone
in which you wish to apply schedule
programming:
Press the OK button.
Turn the knob and select
- Set Comfort T
Press the OK button.
Turn the knob and adjust the room
temperature value during the comfort
period (the temperature value will fl ash
on the display).
Press the OK button to confi rm.
Turn the knob and select:
- Set Reduced T (in heating mode
only)
Press the OK button.
Turn the knob and adjust the room
temperature value during the reduced
period (the temperature value will fl ash
on the display).
Press the OK button to confi rm.
Turn the knob and select:
- Time program
Press the OK button. Turn the knob and
select the day or days of the week you
wish to program.
Every time a day is selected, press the
OK button to confi rm.
The days selected for programming
appear on the display in a box.
Turn the knob and select save. Press
the OK button and turn the knob to set
the start of the heating period corre-
sponding to the fl ashing value. Press
the OK button to confi rm.
Press the OK button and turn the knob
to set the end time of the comfort
period.
If you want to add new time periods,
turn the knob and select Add period;
press the OK button.
Repeat the above procedure to set the
start and end times for each comfort
period added.
Once programming is complete, turn
the knob and select Save.
Press the OK button to confi rm.
Energy suppliers lock-out
The energy supplier is able via an exter-
nal signal (230V signal) to lock tempo-
rarily the compressor.
Frost protection of the system and the
heating circulation pump remains in
operation.
Depending on the contract with the
energy supplier the interruption
can take place up to three times a
day with up to 2h per interruption.
• Signal connection: Connect on "HV
IN 1" the signal of the energy suppli-
er (230V)
• At connection "HV-In 2" for energy
suppliers lock-out no signal is need-
ed
• Parameter 17.1.0 = Input 1 (SG-Ready
1) to be adjusted
• Parameter 17.1.1 = Input 2 (SG-
Ready_ 2) to be adjusted (if only
17.1.0 is adjusted, a fault message
is displayed and the function is not
active, because the used SG-Ready
signal consists of two signals
• Display: SG-Ready symbol is dis-
played
Function: If energy supplier lock-out
is active, at contact HV IN 1 we have
230V, compressor and electrical
resistance are blocked, unless the
signal stops. In the meantime the
allover power supply (e.g. of the
controller) remains.
27 / GB