When the day has been programmed, press the OK button; the item "Save & exit" will be automatically selected (fig. 24).
Use the navigation buttons 5 and 7 to change the previous settings, or press OK to confirm: in this case the display will
again show the day (fig. 16) or the interval of days to be programmed (fig. 17). The same procedure can therefore be
followed to complete the desired weekly program.
To program the next day in the same way, select "Copy to next day" and press OK to confirm (fig. 24).
To reset the time program to the default values, press the contextual button 3 in the Time Program menu
A
(fig. 25) and confirm with OK.
The two Heating and DHW time programs are independent even in case of resetting to default values.
A
Legionella programming (with optional hot water tank installed)
This function must be activated by enabling an installer parameter.
Access the "Legionella" menu through the path "USER MENU
•
Antilegionella Day. Defines the day of the week during which the function will be activated.
•
Time of Antilegionella Day. Defines the function start time.
•
Antilegionella Duration. Defines the duration (in minutes) of the function.
•
Antilegionella Adjustment Temp.. Defines the DHW Adjustment temperature during the function.
130
Scheduler Set
1.
06:00 - 16:00
2.
16:00 - 21:00
21:00 - 06:00
3.
4.
--:-- - --:--
5.
--:-- - --:--
6.
--:-- - --:--
Copy to the Next Day
Save & Exit
to confirm
fig. 23
Scheduler Set
1.
06:00 - 16:00
2.
16:00 - 21:00
21:00 - 06:00
3.
4.
--:-- - --:--
5.
--:-- - --:--
6.
--:-- - --:--
Copy to the Next Day
Save & Exit
to confirm
fig. 24
Scheduler Set
Monday
Tuesday
Wednesdey
Thursday
Friday
Saturday
Sunday
Monday-Sunday
to confirm
fig. 25
cod. 3541T170 - Rev. 00 - 09/2019
5
7
3
"DOMESTIC HOT WATER"
FORCE B
"Legionella" to set:
EN