Temperature Outputs; Call Output (Incall); Analog Pwm Output (Pwm); Optocoupler Inputs (In1 - In2) - Conrad GX106M Notice D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

6.9 4 temperature outputs

see 2 temperature inputs (T1-T2) / 4 temperature outputs (TEMP1-TEMP4)

6.10 1 CALL output (INCALL)

This is the INCALL output, which switches for a defined time as soon as the module is called. Because
the module does not pick up, this is free of charge! You simply call the module and let it ring a few times
to be sure. Then the INCALL output switches on for the set time and then off again automatically. This is
ideal e.g. for a garage door opener or front door light.
The activation time can be set in 12 stages from 0.3 seconds to 24 hours.
With „Anyone may call", this output switches on every call, regardless of whether this is contained in
the telephone list; it even switches if no phone number is transmitted. But you can also select the phone
numbers in your list in TEL that may switch this output. You can directly connect a relay to the output
INCALL (Conrad order no. 502892).

6.11 1 analog PWM output (PWM)

This is the analog output PWM, whose pulse width can be set via SMS (with a fixed refresh rate of
approx. 1.5kHz). The pulse width can be set in 255 steps. If the output is to be set to e.g. 50%, you have
to send the text PWM=128.
„Always switch with password" means that anyone may switch this output who knows and sends the
password, or you select the people in your list at SMS who may switch this output.
6.12 2 optocoupler inputs (IN1 – IN2)
These are the two digital optocoupler inputs IN1 and IN2 for e.g. smoke detectors or burglary detectors
(glass break signallers are usually circuits that are interrupted in case of burglary). A voltage of 0 to 12V
can be connected to the input of the optocoupler. Observe the polarity! The minus pole is connected to
the marking „-", and the plus pole to the marking „+".
Without external voltage (meaning open), this input is HIGH. If an external voltage is connected, the
input becomes LOW and when the circuit is interrupted, HIGH again. If you now set „Message when
input HIGH" is set for the optocoupler input, and the input becomes HIGH due to an interruption of the
circuit, the module can automatically return an SMS, a fax or an e-mail with the entered message text.
(ALARM IN1: DIGITAL1). Only an SMS is sent; when the input returns to LOW and then to HIGH again,
another SMS is sent. This also applies analog in the reverse case, if "Message when input LOW" is set.
No output is switched.