Disconnecting A Microinverter From The Pv Module - Enphase Energy M215 Manuel D'installation Et D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Disconnecting a Microinverter from the PV Module

To ensure the microinverter is not disconnected from the PV modules under load,
adhere to the following disconnection steps in the order shown:
1. Disconnect the microinverter from the Engage Cable.
The AC connectors are tool-removable only. The installation kit
includes a disconnect tool with two prongs. To disconnect a
microinverter from the Engage Cable, insert these two prongs into the
two holes in the AC cable connector. Rock the connector back and
forth while pulling gently to disengage.
2. Cover the PV module with an opaque cover.
3. Using a clamp on meter, verify there is no current flowing in the DC
wires between the PV module and the microinverter.
Take care when measuring DC currents due to the fact that most
clamp-on meters must be zeroed first and tend to drift with time.
4. Disconnect the PV module DC wire connectors from the microinverter
using the Enphase disconnect tool.
5. Remove the microinverter from the PV racking.
WARNING: Do not leave the connector on the Engage Cable uncovered
for an extended period. If you do not plan to replace the microinverter
immediately, you must cover any unused connector with a sealing cap.