Step 5 – Dress the Engage Cable
a. Attach the Engage Cable to the PV racking
using the cable clips, or you may use tie
wraps. The cable clips are designed so that
the connector from the microinverter can
also be dressed into the clip underneath
the Engage Cable.
NOTE: There are two through-holes in the
connector on the cable. These are not for
mounting but are used to disconnect the
connector. Keep these release holes
clear and accessible.
b. Dress any excess in loops so that the
Engage Cable does not contact the roof.
Do not allow the Engage Cable to rest on
the roof. There are several ways to support
the cable. One method is to place tie wraps
or clips on either side of the connector. Use
one or two additional clips, tie wraps, or
other support scheme to secure the cable
between connectors.
c. Remove the temporary shipping caps from
the Engage Cable and connect the
microinverter. There are two latching
mechanisms within the connectors. Listen
for two clicks as the connectors engage.
Ensure that both latching mechanisms
have engaged.