Step 7 – Connect the Engage Cable to AC Junction Box(es)
a. Connect Engage Cable into the AC branch circuit junction box using an
appropriate gland or strain relief fitting. The Engage Cable requires a
strain relief connector with an opening of 1.3 cm (0.5 inches) in
diameter.
b. Connect the Engage Cable into
additional AC junction boxes as
needed to transition to conduit
between smaller sub-arrays.
Refer to the wiring diagrams located
in the Appendix of this manual for
more information.
Wires are identified as follows. For 400 Vac, L1 is sheathed in brown, L2 is
sheathed in black, L3 is sheathed in gray, Neutral is sheathed in blue, and
Protective earth is sheathed in green/yellow. The earthing wire is used to
earth the microinverters. For single phase, L2 and L3 are not present.
NOTE: The green/yellow wire acts as protective earth for the equipment.
Step 8 – Complete the Paper Map
The Enphase Installation Map is a diagrammatic representation of the physical
location of each microinverter in your PV installation. The virtual array in
Enlighten is created from the map you create. Use the blank map in the Appendix
to record microinverter placement for the system, or provide your own layout if a
larger or more intricate installation map is required.

Complete the Enphase Map

a . Each Enphase Microinverter has a removable serial number label
located on the mounting plate. Peel the removable serial number label
from each Enphase Microinverter and affix it to the respective location
on the Enphase installation map (see map on page 27). Remember to
keep a copy of the installation map for your records.

Alternative: Create Your Own Map

a . Draw a top-down view of the array using the Array Map template
(using either the grid on Side A or the freeform area on Side B). Make
sure to leave enough room to place the serial number stickers.
b . When installing the microinverters, remove the serial number labels
located next to the DC input cables and place them in the correct order
on your drawing of the system. Remember to keep a copy of the
installation map for your records.