Step 9 – Connect the PV Modules
NOTE: Completely install all microinverters and all system AC connections
prior to installing the PV modules.
a . Mate the microinverters and PV modules as required.
b . Mount the PV modules above the microinverters. Repeat for all
remaining PV modules using one microinverter for each PV module.
NOTE: The Status LED of each microinverter will blink green six times to
indicate normal start-up operation approximately one minute after DC
power is applied.
REMINDER: Enphase Microinverters will not begin exporting power until the
Envoy Communications Gateway is installed and has detected all of the
microinverters at the site. In addition, the grid profile must be configured and
the Envoy must have propagated these settings to the microinverters.
For instructions on installing the Envoy and configuring the grid profile, refer to
the Envoy Installation and Operation Manual at
http://www.enphase.com/support/downloads.