Parts and Tools Required
In addition to the M215 microinverters, PV modules, PV racking, and associated
hardware, you will need the following items.
Enphase equipment required:
•
Enphase Envoy™ Communications Gateway
•
Engage Cable, as needed
•
Cable clips
•
Sealing caps as needed (for any unused drops on the Engage Cable)
•
Terminators, as needed (one needed at the end of each AC branch circuit)
•
Enphase disconnect tool
Other equipment required:
•
AC Junction boxes
•
Gland or strain relief fitting (one per AC junction box)
•
Earthing conductor
•
Torque wrench, sockets, wrenches for mounting hardware
•
Adjustable wrench or open-ended wrench (for terminators)
•
Tool for PV module locking connectors
•
Handheld mirror (for viewing indicator lights on the undersides of the
microinverters)
•
Laptop or other computer for Envoy set up
Lightning Surge Protection
Lightning protection and resulting voltage surge are protected in accordance with
EN 62305-1. It is assumed that the PV modules are installed in accordance with
related standards and that the microinverter is a part of a broader lightning
mitigation system in accordance with EN 62305-1, -3.
In some areas, the statistical frequency of lightning strikes near a PV installation
is high enough that lightning protection must be installed as part of an Enphase
system. In some areas, a surge protection device might be mandatory following a
risk analysis, according NF C 15-100 (art. 443) & NF C 15-443L.