Step 6 – Terminate the Unused End of the Engage Cable
Perform the following steps to terminate the far end of the Engage Cable.
a. Remove 60mm (2.5 inches) of the cable sheath from the conductors.
b. Slide the hex nut onto the Engage Cable.
c. Insert the Engage Cable
all the way into the wire
organizer (up to the
stop).
d. Bend the individual wires
back into the recesses in
the wire organizer so
that they angle back
toward the cable.
e. Cut the individual wires
so that no excess extends outside of
the wire organizer. The portions that
angle back will need to extend enough
to fit neatly into the 0.5 cm (0.2 in)
recesses in the wire organizer and
flush with the edge of the cap.
f. Screw the hex nut onto the cap.
Never unscrew the hex nut as this
can twist and damage the cable.
g. Hold the cap with an Enphase disconnect tool.
h. Use a 24mm (7/8 inch) wrench to tighten the hex nut until the latching
mechanism is screwed all the way to the base.
i.
Use a tie wrap or cable clip to attach the cable to the PV racking, so
that the Engage Cable and terminator do not touch the roof. Ensure
that all cabling is located underneath the PV module.