Make sure that no consumers are connected.
1. Activate the "Preset" function through the "MODE" (13) slider on the rear. Put the
switch in the "Preset" position. The front LED display "REAR CONTROL" (6) lights
up. The front rotary controls are now inactive.
2. Select the respective memory slot "P1, P2 or P3" on the rear slider. The re-
spective output voltage is indicated on the display (2).
3. Now you can connect and switch on the consumer.
For deactivating the fixed voltage function, slide the "MODE" (13) slider back to the "Normal" position. The LED
display "REAR CONTROL" (6) goes out. The device switches back to normal power unit operation (always remove
DC consumers before!)
Assigning memory slots with "Set"
1
All three memory slots can be assigned user-specific values for output voltage and current limitation.
Make sure that no consumers are connected.
For this purpose, proceed as follows:
1. Activate the "Set" function through the "MODE" (13) slider on the rear. Put
the switch in the "Set" position. The front LED display "REAR CONTROL" (6)
lights up.
2. Select the respective memory slot "P1, P2 or P3" on the rear "RECALL" (15)
slider. The respective values for current and voltage are indicated on the dis-
play (2/3). The front rotary controls (7 and 8) can be used to set the desired
output voltage and current limitation.
If required, repeat these steps with the other memory slots.
3. When all parameters are set, slide the "MODE" (13) slider back to the "Preset" position for fixed voltage operation
or to the "Normal" position for standard operation.
g) Resetting output presets (P1/P2/P3) to factory default values
The power supply allows for presetting three voltage values (including current settings) by means of three memory
slots: P1, P2, and P3. In case you want to reset the memory slots to the factory default values during operation, do
the following.
1. Press and hold the VOLTAGE control knob for approx. 30 s to enter the MENU mode. "CCO" and "no" are dis-
played.