ERROR CODES ON THE COOKING ZONES DISPLAY
Error code
Erxx
or
Ex
(not E2)
E2
U400
Symbol
as per
side
figure
90
Example
What to do
1. Switch off the cooker and disconnect it
from the mains.
2. Wait for about 1 minute, then reconnect
the cooker and turn on the cooking zones.
3. Wait for about 1 minute and if the error
message does not appear again the cook-
ing zones can be used.
4. If the error message does not disappear
repeat step from 1 to 3.
5. If the problem continues do not use the
induction hob (only use the oven) and
contact your Authorised Service Centre.
E and 2 alternating for one or more cooking
zones.
This indicates an overheating of the cooking
zone/s.
1. Switch off the cooking zone/s and leave to
cool.
2. If the problem continues do not use the
induction hob (only use the oven) and
contact your Authorised Service Centre.
The cooker has been incorrectly connected.
The appliance shall be connected to the
appropriate power supply by a qualified
technician.
This indicates an incorrect operation of one
or more cooking zone control knob.
1. Turn the cooking zone control knobs to
the 0 (Off) position, then switch off the
cooker and disconnect it from the mains.
2. Wait for about 1 minute, then reconnect
the cooker and turn on the cooking zones.
3. Wait for about 1 minute and if the error
message does not appear again the cook-
ing zones can be used.
4. If the error message does not disappear
repeat step from 1 to 3.
5. If the problem continues do not use the
induction hob (only use the oven) and
contact your Authorised Service Centre.