M-system MFI 94 Mode D'emploi page 115

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

CONNECTING THE FEEDER CABLE
To connect the feeder cable to the cook-
er it is necessary to:
– Remove the two screws that hold
shield A behind the cooker (Fig. 8.1).
– Open completely the cable clamp D.
– Fitted with a 5-pole terminal block,
position the U bolts onto terminal
block 'B' (fig. 8.1) according to the
diagrams in figs. 8.2 - 8.3.
– Feed the supply cable through the cable
clamp "D". The supply cable must be of
a suitable size for the current require-
ments of the appliance; see the section
"Feeder cable section"
– Connect the phase and earth cables
to terminal B according to the dia-
grams in figs. 8.2 - 8.3.
– Pull the feeder cable and block it with
the cable clamp D
– Re-mount shield A.
N.B. Earth cable must be 3 cm longer
than neutral and live cables.
D
Fig. 8.1
FEEDEER CABLE SECTION
"TYPE H05RR-F"
230 V
230 V 3
400 V 3N
400 V 2N
(**) – Connection with wall box connection.
– Contemporaneity factor applied
B
A
2
3 x 6 mm
(**)
2
4 x 4 mm
(**)
2
5 x 2,5 mm
(**)
2
4 x 4 mm
(**)
230 V
1 2 3 4 5
L
N (L
)
1
2
230 V3
1 2 3 4 5
L
L
L
1
2
3
400 V 3N
1 2 3 4 5
L
L
L
N
1
2
3
400 V 2N
1 2 3 4 5
L
L
N
1
2
Fig. 8.2
PE
PE
PE
PE
115

Publicité

Table des Matières
loading

Table des Matières