Connecting Electricity And Ducting; Re-Circulating Requirements - Sirius SIU3 Notice D'utilisation Et D'entretien

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

This will require two strong people –do
not attempt this step on your own. Brac-
ket "B" has slots, position C per Diagram
"A" (refer to page 5), at the top that will
receive the spring clips located on Brac-
ket "A" –THIS IS A TEMPORARY HOLD
ONLY –DO NOT RELY SOLELY ON THESE
CLIPS TO HOLD THE HOOD UP – THEY
WON'T. Once "hooked" by the spring
clips immediately secure the structure
with the machine screws at point "E" on
the schematic on page 5 – this must be
done immediately and should not be
skipped.
Ensure the entire structure is sturdy- se-
rious injury, death and MAJOR damage
could result should the unit not be well
connected to the frame structure within
the ceiling.
This is of utmost importance – do not go
any further until this has been tested and
double checked – the installer has sole
responsibility for the safe installation of
this product.
Once the entire structure has been fixed
to the ceiling slide the chimneys on the
assembled structure from the bottom up
as per the schematic on page 5. And fix
the chimneys with the screws supplied.
Raise the upper chimney to the ceiling
and fix it to the bracket "A" with the
screws supplied "D".

Connecting Electricity and Ducting.

Make sure power is turned off at the
source. Make the electrical connection
(see figure 2). Test the functioning of the
hood. Slide the upper chimney into place
and attach with the machine screws pro-
vided to Bracket "A".
8
fig. 2

Re-Circulating Requirements.

Fit the carbon filter after the installation is
complete – these fit in behind the alumi-
num grease filter.
A short length of ductwork must be con-
nected from the exhaust outlet up to the
deflector (must be purchased with hood).
The deflector, after attaching part B with
screws E connects to the top of Bracket
"A" and forces the air out through the
grills on the side of the chimney section
back into the room. (see diagram C).

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Siu5Su404Su405Su401Siu14Siu24 ... Afficher tout

Table des Matières