4
Technical data
Rated voltage
Weight including B22⁄8.0 battery
Max. cable diameter
Max. cutting capacity
Storage temperature
Ambient temperature for operation
4.1
Battery
Battery operating voltage
Ambient temperature for operation
Storage temperature
Battery charging starting temperature
5
Operation
5.1
Preparations at the workplace
CAUTION
Risk of injury by inadvertent starting!
▶ Before inserting the battery, make sure that the product is switched off.
▶ Remove the battery before making any adjustments to the power tool or before changing accessories.
Observe the safety instructions and warnings in this documentation and on the product.
5.2
Charging the battery
1. Before charging the battery, read the operating instructions for the charger.
2. Make sure that the contacts on the battery and the contacts on the charger are clean and dry.
3. Use an approved charger to charge the battery.
5.3
Inserting the battery
CAUTION
Risk of injury by short circuit or falling battery!
▶ Before inserting the battery, make sure that the contacts on the battery and the contacts on the product
are free of foreign matter.
▶ Make sure that the battery always engages correctly.
1. Charge the battery fully before using it for the first time.
2. Push the battery into the battery holder until it engages with an audible click.
3. Check that the battery is seated securely.
5.4
Removing the battery
1. Press the battery release buttons.
6
English
NCT IS 053-A22
21.6 V
3.8 kg
(8.4 lb)
50 mm
(2.0 in)
1000 MCM Al/Cu cable, 2" (50
mm) outside diameter
−20 ℃ ... 70 ℃
(−4 ℉ ... 158 ℉)
−17 ℃ ... 60 ℃
(1 ℉ ... 140 ℉)
21.6 V
−17 ℃ ... 60 ℃
(1 ℉ ... 140 ℉)
−20 ℃ ... 40 ℃
(−4 ℉ ... 104 ℉)
−10 ℃ ... 45 ℃
(14 ℉ ... 113 ℉)
2188461
*2188461*