Self Help Guide, (Fig.8.1).
Fault code
Possible cause
The batteries need charging, or there is a bad connection to the battery. Check the connections to
the battery. If the connections are good, try charging the batteries
The left hand motor has a bad connection. Check the connections to the left hand motor.
The left hand motor has a short circuit to a battery connection. Contact your Sunrise Medical
Authorised Dealer
The right hand motor has a bad connection. Check the connections to the right hand motor.
The right hand motor has a short circuit to a battery connection. Contact your Sunrise Medical
Authorised Dealer
The wheelchair is being prevented from driving by an external signal. One possibility is that the
battery charger is plugged in.
A joystick fault is indicated. Make sure that the joystick is in the centre position before switching on
the control system
A control system fault is indicated. Make sure the control system connections are secure.
The parking brakes have a bad connection. Check the parking brake and the motor connections.
Make sure that the control system connections are secure
An excessive voltage has been applied to the control system. This is usually caused by a poor
battery connection. Check the battery connections
+ S
+ A
R-net Control
Please refer to your R-net Owner's Manual for details.
Rev.C
S=Speed indicator LED's
A communication fault is indicated. Make sure that the joystick cable is securely connected
and not damaged
A=Actuator LED's
An actuator trip is indicated. If more than one actuator is fitted, check which actuator is not
working. Check the actuator wiring.
Fig.8.1
45
ZIPPIE SALSA M
Mini
2