• Use of the device is prohibited to persons known to be of unsound mind, or suffering from
sensibility disorders, to permanently or temporarily disabled persons unless assisted by
qualified personnel (e.g. a doctor or therapist).
• Use of the device is prohibited in the presence of signs of deterioration of the device itself,
cables and electrodes.
Should any foreign materials penetrate the device contact the retailer or manufacturer
immediately. If dropped down, check that the housing is not cracked or damaged in any way; if
so, contact the retailer or manufacturer.
Should you notice any changes in the device's performance during treatment, interrupt the
treatment immediately and consult the retailer or manufacturer.
• Use of the device is prohibited in combination with other medical devices.
• Use of the device is prohibited close to flammable substances or in environments with high
concentrations of oxygen, with aerosoltherapy devices or in wet environments (use of the
device is prohibited in bathroom or shower areas).
• Consult a doctor before using MIO-CARE with metallic osteosynthesis devices.
Muscle heaviness and cramps may be experienced in the event of prolonged muscle
stimulation. Should this occur we recommend to suspende treatment with MIO-CARE for a few
days.
Make sure that the plug and battery charger are intact. Should one of these parts show any
sign of damage, suspend use of the battery charger immediately and contact the retailer or
manufacturer.
Only use battery chargers supplied by the manufacturer; the use of battery chargers not
supplied by the manufacturer will free the same from any responsibility related to damage to
the equipment or user, and will expose the user to risks such as short circuits and fire.
• It is forbidden to position the electrodes in such a way that the current crosses the heart area
(e.g. a black electrode on the chest and a red electrode on the shoulder blade); however
electrodes can be positioned along the muscular fascia of the heart area, as used for
pectoral strengthening.
• Use of the device is prohibited with electrodes positioned on or close to injuries or cuts.
• The electrodes must not be positioned on the carotid sinuses (carotid) or genitals.
• The electrodes must not be positioned close to the eyes; make sure that the current
delivered does not cross the eyeball (one electrode diametrically opposite to the other in
relation to the eye); keep a distance of at least 3 cm. from the eyeball.
• When using the electrodes, follow the instructions given in this manual and on the package of
the electrodes. Use single-patient electrodes, supplied exclusively by the manufacturer, and
take care to avoid the exchange of electrodes between different users. MIO-CARE has been
tested and guaranteed for use with the electrodes supplied.
• Insufficiently sized electrode sections can cause skin reactions or burns. Only use the round
electrodes supplied by the manufacturer for facial applications.
• Do not use electrodes when damaged, even if they stick to the skin well.
• Apply only undamaged electrodes to clean and dry skin.
• Electrodes must not be used when they no longer stick to the skin.
• Pay attention to use connexion cables with children/young people: strangulation danger.
• Repeated use of the same electrodes can compromise the safety of the stimulation, in fact it
can cause skin redness that can last for many hours after stimulation.
• Warning! During treatment with round and 41x41 mm. electrodes, current density may be in
excess of 2 mA/cm² for each electrode. In these cases take special care regarding any skin
redness.
• Keep right distance between electrodes: the contact between electrodes could cause wrong
stimulations or irritations/burns.
IACER S.r.l.
42
MNPG95 Rev. 01 Ed. 28/09/12