Technical Data

Gas Turbine GGH 10 L
Art. No ................................................................................................................................................................................................85112
Service connection ..................................................................................................................................................230 V~50 Hz
Max. Power ..................................................................................................................................................10 kW (8600 kcal./h)
working pressure ...........................................................................................................................................................700 mbar
Type of gas .........................................................................................................................................................Propane/butane
consumption .............................................................................................................................................................ca. 0,73 kg/h
Fan power ..........................................................................................................................................................................580 m3/h
Degree of protection ..............................................................................................................................................................IPX4
Weight .......................................................................................................................................................................................3,8 kg
Read and understand the operating instructions
before using the appliance. Abide by all the safety
measures stated in the service manual. Act responsib-
ly toward third parties.
In case of any doubts about connection and operati-
on refer please to our customer center

Specified Conditions Of Use

Only use outdoors and away from combustible materials.
Do not use this product in any other way as stated for
normal use. Respecting technical data and safety pre-
cautions.Not observing general regulations in force
and instructions from this manual does not make the
manufacturer liable for damages.
The gas heater must not be used:
For heating of closed or occupied rooms (resi-
dential buildings) or operation in these areas;
In the vicinity of combustible materials (e.g.
paper, building materials);
An explosive atmosphere may be created in
places where volatile materials (e.g. gasoline,
solvents, chemicals) are stored or present;
After an arbitrary structural change in the gas
heater;
In case of wrong, unauthorised connection to
a gas source
In places that are not sufficiently ventilated.
As a source of heat for events and festivals.
Power tool description
1.
Handle
2.
Protective grille
3.
Piezzo
4.
fan switch
5.
Gas valve knob
6.
gas hose
7.
Reducer

Emergency procedure

Conduct a first-aid procedure adequate to the injury
and summon qualified medical attendance as quickly
as possible. Protect the injured person from further
harm and calm them down. For the sake of eventual
accident, in accordance with DIN 13164, a workplace
has to be fitted with a first-aid kit. It is essential to
replace any used material in the first-aid kit immedia-
tely after it has been used.
If you seek help, state the following pieces of infor-
mation:
1. Accident site
2. Accident type
3. Number of injured persons
4. Injury type(s)